LAMY RHEOLOGY company is
specialized in the trade of scientific materials since 1957,
with very quickly , a dominating share given to the Rheology
activity.
Since 2006, all the range of
the rotative viscometers and rheometers of LAMY RHEOLOGY are
developed and manufactured in France, in our buildings
located close to Lyon; it is diffused in the whole world,
thanks to effective partners.
|
|
 |
Lamy Rheology, France |
|
|
|
Universal
rotative Viscosimeter without spring or
tossion rod, with integrated calculator
and sérial and USB outputs ; It is
conformed to all normatives: ASTM /
ISO2555 spindles, DIN / ISO 3219, MS-R,
and it read Temperature of sample.
|
|
Measuring princip |
rotational viscometer |
|
Rotation speed |
34 speeds:
0.3-0.5-0.6-1-1.5-2-2.5-3-4-5-6-10-12-20-30-40-50-60-100-200-250-300-400-500-600-700-800-900-1000-1100-1200-1300-1400-1500
rpm |
|
Torque range |
0.05 to 10 mNm |
|
Temperature |
by integrated Pt 100, from -20
to 120°C |
|
Digital output |
T°c, speed or Shear rate,
Torque, Viscosity |
|
Viscosity range |
from 1 mPa.s to 510 M mPa.s |
|
Supply voltage |
110-220 VAC |
|
PC connexion |
Serial or USB port |
|
Printer connexion |
Parallel port |
|
Other detail |
Rheomatic-A software enables
ASCII data transfer to PC. |
|
 |
Viscometer
RM100 + Peltier
CP100
Associated to the CP100 Cone-Plate
system, thermostated by Peltier Effect,
enables easy viscosity measurements on
small quantities of sample with quick
temperature transition.
|
|
Measuring princip |
Speed imposed and Peltier
effect. |
|
Rotation speed |
34
speeds:0.3-0.5-0.6-1-1.5-2-2.5-3-4-5-6-10-12-20-30-40-50-60-100-200-250-300-400-500-600-700-800-900-1000-1100-1200-1300-1400-1500
tr/mn |
|
Torque range |
0 to 30 mNm |
|
Temperature |
5 to 80° C +/- 0.2°C. |
|
Digital output |
All standard parameters. |
|
Viscosity range |
10 - 20 000 mPa.s according used
cone. |
|
Supply voltage |
110-220 VAC. |
|
PC connexion |
Serial and USB output. |
|
Printer connexion |
Parrallel output. |
|
Other detail |
Without circulating fluid. RM100
could be used with other
systems: ASTM/ISO2555 or DIN/ISO
3219. This configuration answers
to the standard: ASTM D4287, ISO
2884 Industrial control of
coatings to 10 000 s-1. "ICI
Sandard". |
|
 |
|
Shear rate imposed
Rheometer, with a wide spedds range from
0.5 to 1500 rpm, parallel, serial and
USB port.
It enables automatic flow
curves and their fitting without PC
|
|
Measuring princip |
rotative princip |
|
Rotation speed |
from 0.3 to 1500 rpm |
|
Torque range |
from 0 to 30 mNm |
|
Temperature |
by integrated Pt100, from -20 to
120°C |
|
Digital output |
T°C, Shear rate, Torque,
Viscosity, Yield value |
|
Viscosity range |
from 1 to 510 M mPa.s |
|
Supply voltage |
110-220 VAC |
|
PC connexion |
Serial and USB port |
|
Printer connexion |
Parallel port |
|
Other detail |
Rheomatic-T software
enables to transfer data from
RM200 to PC.
Rheomatic-P software
drives the RM200 from a PC. |
|
 |
|
Modular
and universal Rheometer, with a wide
range of shear rate from 0.05 to 150 000
s-1, according used geometries.
It could
replace RM115 or RM260 Rheomat, and
works on RT300 oven or Cône-plate stativ.
|
|
Measuring princip |
rotative princip |
|
Rotation speed |
From 0.1 to 1500 rpm |
|
Torque range |
0.05 to 30 mNm |
|
Temperature |
Pt 100 in the measuring cups
from -20 to 120°C |
|
Digital output |
T°C, Shear rate, Torque,
Viscosity |
|
Viscosity range |
1 to 53 M mPa.s |
|
Supply voltage |
110-220 VAC |
|
PC connexion |
serial and USB port |
|
Printer connexion |
Parallel port |
|
Other detail |
Drived from a PC by
Rheomatic-P Software.
Many accessories of
measurement or for
thermostatisation. |
|
 |
Rheometer
RM300 with CP100
Peltier
Cone-Plate
system
Associated to CP100 Cone-Plate system ,
thermostated by Peltier Effect, the
RM300 Rheomat enables rheological
studies on small quantities of sample
with very fast temperatures changes.
|
|
Measuring princip |
Shear rate imposed and Peltier
Effect. |
|
Rotation speed |
0.1 to 1500 rpm |
|
Torque range |
0.05 to 30 mNm |
|
Temperature |
5 to 80° C +/- 0.2°C. |
|
Digital output |
All standard parameters. |
|
Viscosity range |
10 - 150 M mPa.s according using
cone. |
|
Supply voltage |
110-220 VAC. |
|
PC connexion |
Serial and USB output. |
|
Printer connexion |
Parrallel output. |
|
Other detail |
Without circulating fluid. Could
be added to the ST100
thermostating stand for coaxial
systems. Could be drived by
Rheomatic-P software. |
|
 |
|
|
|
|
|